WorldWideWire

Tel (760) 832-1798 • Fax (760) 328-9830 • info@WorldWideWire.com • Jonathan Trigiano, CEO


High Temp Wire - TGGT

Description: TGGT Cable may be used for internal wiring of commercial, industrial and household ovens, cooking and drying equipment. TGGT Cable is suited for severe hot spot locations in industrial processing.


Specification:
Meets UL subject 758 ( AWM )
UL5196 / UL5251
Conductor:
Nickel Coated Copper
Insulation: PTFE tapes covered by fiberglass covers with fiberglass (hi-temp) braid jacket overall.
Temperature Rating
Voltage Rating
Standard Spool Put-Up
250°C
600 Volts R.M.S.
1000 ft.

AWG
Size
Conductor
Stranding
Insulation
Mils-Nom.
Glass
Serve
Glass
Jacket
Overall
Diameter
AMPS
Weight
LBS/MFT
UL
Style
22 7/.0100 0.015 0.010 0.005 0.092 12 8 5196
20 10/.0100 0.015 0.010 0.005 0.100 16 10 5196
18 16/.0100 0.015 0.010 0.005 0.110 23 13 5196
16 26/.0100 0.015 0.010 0.005 0.120 29 17 5196
14 41/0100 0.015 0.01 0.005 0.135 40 23 5196
12 65/.0100 0.015 0.01 0.005 0.155 55 32 5196
10 105/.0100 0.015 0.010 0.005 0.180 75 48 5196
8 133/.0111 0.015 0.010 0.005 0.230 95 72 5176
6 133/.0142 0.020 0.015 0.0075 0.300 135 120 5196
4 133/.0177 0.020 0.015 0.0075 0.335 175 175 5196
2 133/.0223 0.020 0.015 0.0075 0.425 230 270 5251
1 259/.0177 0.020 0.015 0.010 0.470 290 340 5251
1/0 259/.0202 0.020 0.015 0.010 0.515 350 415 5251
2/0 259/.0229 0.020 0.015 0.010 0.570 410 510 5251
3/0 259/.0255 0.020 0.015 0.010 0.625 480 630 5251
4/0 259/.0286 0.020 0.015 0.010 0.690 560 780 5251


Return to: High Temperature Wire | Products